Zhejiang Jiangshan Hengli Electrical Co., Ltd. is one of the leading manufacturers and suppliers of low loss distribution transformer in China. If you're going to wholesale durable low loss distribution transformer made in China, welcome to get pricelist from our factory. All customized products are with high quality and low price.
Our amorphous alloy transformers use an amorphous metal core instead of a conventional grain-oriented silicon steel core. The core's magnetic properties make it suitable for transformer designs focused on reducing no-load losses.
No-load loss occurs whenever a transformer is energized, even when the connected load is low. For distribution systems with long operating hours, this loss is an important factor in transformer selection.
Common three-phase SBH15-M designs use oil-immersed construction and offer a range of capacity, voltage and connection configurations. We provide transformer selection and design support for projects requiring amorphous alloy transformer solutions.
Key Features
Amorphous Alloy Core
The amorphous alloy core is the defining feature of this transformer type. Its low core-loss characteristics make it relevant to distribution networks where transformers remain energized for extended periods.
Reduced No-Load Losses
Reducing no-load loss helps limit the energy consumed while a transformer is energized but operating at light load or without a connected load. Buyers can compare the no-load loss values against the expected operating hours and load profile of their distribution system.
Three-Phase Oil-Immersed Construction
Common SBH15-M designs feature three-phase oil-immersed construction, with medium-voltage input and low-voltage output. Capacity, voltage combination and connection group can be selected according to the distribution system.
Technical Specifications
The following table presents common three-phase oil-immersed SBH15-M design configurations.
| Parameter | Common Design Options |
|---|---|
| Transformer type | Amorphous alloy distribution transformer |
| Phase | Three-phase |
| Construction | Oil-immersed |
| Rated capacity | 30, 50, 63, 80, 100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500 kVA |
| High voltage | 6, 6.3, 10, 10.5 kV |
| Low voltage | 0.4 kV |
| Frequency | 50 Hz |
| High-voltage tapping range | ±5%; ±2 × 2.5% |
| Vector group | Dyn11; Yyn0 available in some designs |
| No-load current | 0.20%–1.70%, depending on rated capacity |
| Short-circuit impedance | 4% for 30–500 kVA; 4.5% for 630–1600 kVA; 5% for 2000–2500 kVA |
| Core structure | Three-limb or five-limb |
| Winding conductor | Copper conductor; low-voltage copper-foil winding design |
| Installation | Indoor or outdoor, according to the selected design and operating conditions |
No-Load Loss by Rated Capacity
| Rated Capacity (kVA) | No-Load Loss (W) | No-Load Current (%) |
|---|---|---|
| 30 | 33 | 1.70 |
| 50 | 43 | 1.30 |
| 63 | 50 | 1.20 |
| 80 | 60 | 1.10 |
| 100 | 75 | 1.00 |
| 125 | 85 | 0.90 |
| 160 | 100 | 0.70 |
| 200 | 120 | 0.70 |
| 250 | 140 | 0.70 |
| 315 | 170 | 0.50 |
| 400 | 200 | 0.50 |
| 500 | 240 | 0.50 |
| 630 | 320 | 0.30 |
| 800 | 380 | 0.30 |
| 1000 | 450 | 0.20 |
| 1250 | 530 | 0.20 |
| 1600 | 630 | 0.20 |
| 2000 | 750 | 0.20 |
| 2500 | 900 | 0.20 |
Configuration and Customization
We provide transformer selection and design support for different project requirements. The main configuration points include:
- Rated capacity: Common SBH15-M options range from 30 to 2500 kVA.
- Voltage combination: High-voltage options include 6, 6.3, 10 and 10.5 kV, with 0.4 kV low-voltage output in the listed designs.
- Tapping arrangement: ±5% or ±2 × 2.5%.
- Vector group: Dyn11 or Yyn0 in designs offering this connection.
- Core structure: Three-limb or five-limb.
- Winding design: Copper conductor or low-voltage copper-foil winding.
These choices allow the transformer configuration to be evaluated against the project's rated capacity, network voltage and connection requirements.
Applications and Selection
Amorphous alloy distribution transformers are suitable for evaluating where reducing no-load losses is an important part of the energy consumption requirements. Typical applications include:
- Utility distribution networks: Distribution points where transformers remain energized for long operating periods.
- Rural electrification: Local power distribution networks with extended operating hours and changing load levels.
- Industrial facilities: Distribution systems supplying factory and industrial-site loads.
- Commercial buildings and infrastructure: Building distribution systems and supporting infrastructure networks.
When selecting a transformer, compare rated capacity, primary and secondary voltage, frequency, vector group, tapping range and short-circuit impedance. The expected load profile and installation environment are also important selection factors.
Manufacturing and Technical Support
We have been manufacturing transformers since 2003. Our product range includes amorphous alloy transformers, oil-immersed distribution transformers, dry-type transformers, power transformers and combined transformer substations.
Our key technical team members have more than 10 years of experience in the transformer industry. Our operations follow ISO 9001 quality management, ISO 14001 environmental management and ISO 45001 occupational health and safety management systems.
We provide product selection consultation, technical communication, design support and relevant technical documentation to help buyers define transformer requirements for their projects.
Request a Quote
Send us your required capacity, high-voltage and low-voltage ratings, frequency, quantity and installation conditions. You can also include your preferred vector group, tapping range and other project requirements.
We will review your enquiry and provide product selection and quotation support.
Hot Tags: low loss distribution transformer, China low loss distribution transformer manufacturers, suppliers, factory, Cast Resin Amorphous Unit, Hermetically Sealed Amorphous Unit