Zhejiang Jiangshan Hengli Electrical Co., Ltd. is one of the leading manufacturers and suppliers of dry type step up and down distribution transformer in China. If you're going to wholesale durable dry type step up and down distribution transformer made in China, welcome to get pricelist from our factory. All customized products are with high quality and low price.
A Dry Type Step Up And Down Distribution Transformer is designed to increase or decrease AC voltage according to the requirements of an electrical distribution system. With a dry-type insulation design, it is an option for installations where insulating oil is not preferred, including indoor electrical rooms, industrial facilities, and selected renewable energy projects.
Unlike a transformer intended for only one predefined voltage ratio, a step-up or step-down distribution transformer is selected according to the relationship between the source voltage and the required output voltage. The appropriate configuration depends on the application, rated capacity, load characteristics, and electrical system design.
Zhejiang Hengli Electrical provides power transformer solutions for different distribution requirements. You can provide your voltage levels, load demand, installation conditions, and applicable standards for technical review before confirming a suitable configuration.
General Technical Parameters
The following values are common industry reference options, not confirmed specifications for every model.
| Rated Capacity | Up to 5000kVA, subject to model availability |
| Primary Voltage | Up to 35kV, common distribution levels include 400 V, 415 V, 690 V, 6kV, 10kV, and 11kV |
| Secondary Voltage | Selected according to the required step-up or step-down ratio |
| Rated Frequency | 50 Hz or 60 Hz |
| Number of Phases | Three-phase |
| Insulation Type | Dry-type insulation; epoxy resin cast construction is one common option |
| Cooling Method | AN (air natural) or AF (air forced), depending on design |
| Vector Group | Dyn11 is a common distribution configuration; alternatives depend on system requirements |
| Installation | Indoor applications, subject to the enclosure and environmental conditions |
| Applicable Standard | IEC may apply to dry-type transformers, depending on product scope and compliance |
Final ratings, losses, impedance, temperature rise, insulation level, and enclosure protection should be confirmed in the technical specification.
Construction and Operating Characteristics
The main components include a magnetic core, high-voltage and low-voltage windings, an insulation system, structural supports, and an optional protective enclosure. Depending on the design, the windings may use cast-resin insulation or another suitable dry-type insulation arrangement.
The winding ratio determines whether the transformer steps voltage up or down. Correct terminal connections and the specified vector group are essential to ensure compatibility with the connected electrical system. Buyers should also consider ventilation, ambient temperature, available installation space, and load conditions when selecting a unit.


Key Features and Advantages
Oil-free insulation design
Eliminates insulating oil, avoiding oil leakage and oil-related servicing requirements.
Flexible voltage conversion
Can be specified for step-up or step-down applications, helping match equipment voltage requirements with the available power supply.
Suitable for selected indoor installations
Dry-type construction can be advantageous in buildings and electrical rooms where oil handling is undesirable. Actual fire performance depends on the insulation materials and complete product design.
Application-based configuration
Voltage ratio, rated capacity, cooling method, impedance, and connection arrangement can be evaluated against project requirements.



Applications
A Dry Type Step Up And Down Distribution Transformer may be considered for:
- Industrial machinery and production lines
- Commercial buildings and electrical distribution rooms
- Solar power systems and other renewable energy installations
- Equipment requiring voltage matching
- Industrial facilities with different supply and operating voltage levels
Application reference: Where equipment requires a different voltage from the available supply, the transformer rating should be selected based on the input voltage, required output voltage, total load, starting current, and expected load growth.
Testing & Quality Assurance
We support personalized customization on voltage ratio, tapping range, protection grade, loss parameter, frequency, color and structural size. Each transformer undergoes strict testing procedures before delivery:
Routine tests (Factory Test)of transformer
1,Winding Resistance Measurement
2,Ratio Test (Voltage Ratio Measurement)
3,Transformer vector group test
4,Short-Circuit Impedance & Load Loss Test
5,No-Load Loss & No-Load Current Test
6,Insulation Resistance Test
7,Tests on-load tap-changer.
8,Oil pressure test on transformer to check against leakages past joints and gaskets
All products comply with IEC 60076 standard, and all other major international standard.




Certificates




FAQ
Hot Tags: dry type step up and down distribution transformer, China dry type step up and down distribution transformer manufacturers, suppliers, factory, dry type furnace transformer, dry type self cooled transformer, dry type transformer custom design, dry type transformer high ambient, Epoxy Resin Cast Delta Star Dry Type Transformer, Epoxy Resin Cast Dry Type Transformer